Lic: E.C No. 8921/2018/2936
24/7:+91 9310861858
Testing & Commissioning Fleet⚡ 24/7 Breakdown Mobilization

On-Site Transformer Services, Breaker Retrofits & Protection Relay Testing

Specialized electrical engineering field services across India. From 2500 LPH mobile transformer oil filtration and intelligent ACB retrofits to 100kV dielectric hipot verification and numerical relay calibration — executed under certified Class-A electrical contractor licenses.

✓NABL Traceable Test Certificates
✓CEIG & CEA Safety Compliance
✓Zero-Interruption Retrofit Adapters
Manki Engineers Site Testing and Breaker Retrofit Team
Field Crew Mobilized 24/7
Field Diagnostic LaboratoryNABL Traceable

Mobile testing vans equipped with motorized 100kV sets, CRM meters, secondary injection kits, and transformer filtration plants.

2500 LPH
Mobile Filtration Plant
High-vacuum transformer oil dehydration
100 kV
HV Hipot Capacity
Dielectric withstand & insulation testing
100% NABL
Traceable Fleet
Annual recalibration certified sets
< 4 Hours
Emergency Dispatch
Breakdown mobilization for industrial plants
Specialized Field Capabilities

Diagnostic Testing, Transformer Services & Switchgear Retrofits

Eliminate unplanned industrial outages. Our certified engineers bring precision testing instrumentation and mobile plants directly to your facility floor.

High-Vacuum Transformer Oil Filtration Van and Dielectric BDV Testing
Transformer Life Extension
⚡ 2500 LPH Plant • BDV > 70kV

High-Vacuum Transformer Oil Filtration & Dehydration

On-site transformer oil regeneration utilizing a multi-stage high-vacuum mobile dehydration plant. Removes dissolved gases, moisture, suspended carbon particles, and sludge to restore dielectric breakdown voltage (BDV) above 70kV while extending transformer operational lifespan.

Key Deliverables & Engineering Scope:
  • ✓Two-Stage High-Vacuum Heating & Dehydration (2500 LPH Flow Rate)
  • ✓Pre & Post Dielectric Breakdown Voltage (BDV) Certification
  • ✓Dissolved Gas Analysis (DGA) & Karl Fischer Moisture (<10ppm) Sampling
  • ✓Transformer Gasket Overhauls, Silica Gel Breathers & Bushing Maintenance
ACB Retrofit and Switchgear Maintenance Operations
Switchgear Modernization
⚡ 415V to 33kV • Zero Busbar Alteration

Air Circuit Breaker (ACB) & VCB Retrofitting & Modernization

Engineered retrofits replacing obsolete, high-maintenance breakers (English Electric, older C&S, Alstom, L&T) with modern micro-processor trip unit breakers. Specialized roll-in replacement cradles and custom copper busbar adapters eliminate shutdown risks.

Key Deliverables & Engineering Scope:
  • ✓Engineered Roll-In & Draw-Out Cradle Conversions (800A to 4000A)
  • ✓Microprocessor Electronic Trip Units (ETU) with LSIG Protection Curves
  • ✓Secondary Disconnect Terminal Alignment, Interlocks & Shunt Trips
  • ✓Factory-Trained Retrofit Engineers with Minimal Shutdown Downtime
Field Engineers Conducting Numerical Relay Testing with Secondary Injection Set
Protection Scheme Audits
⚡ Microprocessor & Numerical Relays

Protection Relay Testing & Primary/Secondary Current Injection

Comprehensive diagnostic calibration of numerical, static, and electromechanical protection relays. Multi-phase current injection sets and calibrated timing kits ensure discrimination between primary and backup protection devices.

Key Deliverables & Engineering Scope:
  • ✓Primary Current Injection up to 2000A for CT Ratio & Polarity Validation
  • ✓Secondary Current Injection for Overcurrent (50/51) & Earth Fault (50N/51N)
  • ✓Transformer Differential (87T), REF & Voltage/Frequency Relay Calibration
  • ✓Certified Dynamic Trip Time Characteristic Curves & NABL Reports
Electrical Substation AMC and Contact Resistance Testing
Asset Health Management
⚡ Comprehensive & Non-Comprehensive

Annual Maintenance Contracts (AMC) & Diagnostic Audits

Structured preventive maintenance regimens for industrial substations, high-rise buildings, and manufacturing plants. Includes Contact Resistance Meter (CRM) audits, dynamic circuit breaker timing, insulation resistance (IR) trending, and statutory CEIG renewal audits.

Key Deliverables & Engineering Scope:
  • ✓Digital Contact Resistance Testing (CRM 100A) on Breaker Main Contacts
  • ✓Dynamic Open/Close Travel Curve & Contact Bounce Timing Verification
  • ✓Pre-Monsoon Substation Yard Overhaul & Transformer Neutral Grounding Audits
  • ✓Infrared Thermographic Hotspot Audits & Statutory CEIG Compliance Files
Calibrated In-House Fleet

NABL-Traceable Electrical Diagnostic Testing Instruments

We own, maintain, and mobilize our own specialized testing laboratory equipment. Every instrument undergoes annual calibration with traceable certificates submitted with all field test reports.

View Full 15-Item Testing Fleet→
High Voltage 100kV Dielectric Hipot Test Set
SL No. 1
Calibration: Annual NABL Traceable

High Voltage (HV) Tester up to 100kV

Motorized 0 - 100kV AC/DC Hipot Set

Test Range:0 to 100kV continuous variable, leakage current up to 100mA
Applicable Standards:IS 2026 / IEC 60060-1
Testing & Diagnostic Purpose:

Dielectric withstand & breakdown testing of HT switchboards, vacuum interrupters, busducts, and extra-high-voltage power cables

Proven Industrial Deployment Scope:

Substations up to 400kV, Thermal Power Plants (NTPC Kudgi, Panki TPS)

Critical Outage Rapid Response

Substation Trip, Transformer Fault, or Main Breaker Breakdown?

Unplanned downtime costs millions per hour in heavy manufacturing. Our 24/7 emergency response team mobilizes within 2 to 4 hours with calibrated diagnostic test sets, spare retrofit kits, and specialized engineers to restore energization safely.

⚡ < 4 Hr Dispatch
PAN India & Industrial Corridor Coverage
🔬 Mobile Van Lab
100kV Hipot, CRM & Relay Injection Kits
📜 CEIG Safety Signoff
Class-A Electrical Contractor Certification
Proven Field Track Record

Real-World Testing, Retrofit & Commissioning Case Studies

Industrial plants, thermal power stations, and commercial complexes trust Manki Engineers for zero-defect electrical field engineering.

Explore All 30+ Executed Projects→
11kV VCB Switchgear Overhaul, Relay Coordination & Contact Audits
Switchgear Overhaul
🏢 Gumia Explosives / Industrial Chemical Plant

11kV VCB Switchgear Overhaul, Relay Coordination & Contact Audits

Comprehensive on-site overhaul of indoor 11kV vacuum circuit breakers, dynamic open/close timing verification, CRM contact resistance audits, and re-setting of numerical overcurrent relays.

Verified Field Results:
  • ✓Restored breaker contact timing within 45ms IEC tolerance
  • ✓Micro-ohm CRM resistance reduced by 35% via contact alignment
  • ✓Zero unplanned trips during subsequent explosive chemical production cycle
WFGD HT Switchgear Pre-Commissioning & Secondary Current Injection
Power Utility Testing
🏢 NTPC Kudgi Super Thermal Power Station (3x800MW)

WFGD HT Switchgear Pre-Commissioning & Secondary Current Injection

Full pre-commissioning diagnostic testing of 3.3kV & 415V auxiliary switchgear panels for flue gas desulfurization (WFGD) package. Performed CT ratio/polarity, secondary injection, and busbar hipot.

Verified Field Results:
  • ✓100% test reports verified and approved by NTPC site engineering head
  • ✓Calibrated primary CT loops preventing false trips during plant synchronization
  • ✓Certified zero dielectric breakdown across 415V PMCC and MCC panels
Ash Handling Plant Substation 33kV/11kV Hipot & Cable Testing
HT Cable & Substation Hipot
🏢 Panki Thermal Power Station (1x660MW Supercritical)

Ash Handling Plant Substation 33kV/11kV Hipot & Cable Testing

Field diagnostic verification of 33kV HT XLPE power cables, motorized 100kV dielectric hipot withstand testing, transformer neutral grounding resistance audits, and CEIG energization clearances.

Verified Field Results:
  • ✓100kV AC/DC continuous variable dielectric test with zero leakage faults
  • ✓Complete substation grounding grid resistance verified below 0.8 Ohms
  • ✓Expedited statutory CEIG safety certification for early unit commissioning
⚡ Certified Field Engineering Services

Ready to Upgrade Your Switchgear, Restore Transformer BDV, or Schedule a Testing Crew?

Connect directly with our senior site engineers. Receive customized technical proposals, calibrated test schedules, and transparent mobilization estimates within 24 hours.

📍 Headquarters: Jamshedpur & Delhi NCR
⚡ Multi-State Class-A Contractor Licenses
📜 NABL Calibration Assured